changes :
	OCPP new Revision
	BootLoader compitibility version 

Release note of model: ACTYPE2 -1Gun
Date: 22-11-2022
Bootloader_HYBD_AEPLv3.2.0-3G

///////////////////////////////////////////////////////////////////////////////////////////////

Hardware Version: rev V3.0
**************************************************************************************
Application Firmware version: V3.4.0
Reference firmware version: V3.0
hex file Path: Y:\EV Production Data\FOTA\V3.4.0_HYBRID-AC001-2G-Type2-1G
-------------------------------------------------------------------------------------
New Added/Changes in Firmware:
1. Serial number & Vendor ID can be modify using HMI for OCPP


-------------------------------------------------------------------------------------
Correction in Firmware:
1. Modifications in billing calculation of energy KWH
2. Connector ID changed to 1 for OCPP
3. reservationId bit set to 0 in StartTransactionreq in OCPP.(Change it to 1 for apple energy firmware)

------------------------------------------------------------------------------------
Notes:
1. Tested with Electreefi CMS
2. FOTA implemented and tested 
3 . Earth Leakage Problem Solved.
-------------------------------------------------------------------------------------

*************************************************************************************
Bootloader supported firmware version: Bootloader_HYBD_AEPLv3.2.0-3G
-------------------------------------------------------------------------------------
New Added/Changes in Firmware:
1. OCPP1.6j changes According to New Edition

-------------------------------------------------------------------------------------
Correction in Firmware:
1. RFID Tag Memory Mapping with External Memory

-------------------------------------------------------------------------------------
*************************************************************************************
Supported Dwin HMI firmware Version : V3.2.0

-------------------------------------------------------------------------------------
New Added/Changes in Firmware:
1. Added production screen for vendor ID and serial no data entry


-------------------------------------------------------------------------------------
Correction in Firmware:
1. changed int to unsigned int and limit changed to 5 from 3 for total energy consumed in bill screen
2. Resolve space issue in gun 3 billing screen


-------------------------------------------------------------------------------------
/////////////////////////////////////////////////////////////////////////////////////